VMware 3V0-41.19 Exam Overview:
| Certification Vendor: | VMware |
|---|---|
| Exam Name: | Advanced Design NSX-T Data Center 2.4 |
| Exam Number: | 3V0-41.19 |
| Exam Format: | Scenario-based items, Multiple choice, Drag and drop |
| Passing Score: | 300 / 500 |
| Real Exam Qty: | 60 - 70 |
| Certificate Validity Period: | 2 years |
| Available Languages: | English |
| Exam Price: | $450 USD |
| Exam Duration: | 135 minutes |
| Related Certifications: | VMware Certified Professional - Network Virtualization 2019 (VCP-NV 2019) VMware Certified Design Expert - Network Virtualization (VCDX-NV) |
| Recommended Training: | VMware NSX-T Data Center: Install, Configure, Manage [V2.4] VMware NSX-T Data Center: Design [V2.4] |
| Exam Registration: | Pearson VUE Registration VMware Certification Portal |
| Sample Questions: | ![]() |
| Exam Way: | Proctored exam: Online remote proctored or onsite at Pearson VUE test centers |
| Pre Condition: | VCP-NV certification or equivalent experience with NSX-T/vSphere; recommended 2+ years of network virtualization design experience |
| Official Syllabus URL: | https://www.vmware.com/education-services/certification/vcap-nv-design-2019-exam.html |
VMware 3V0-41.19 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Planning and Designing | 35% | - Security and micro-segmentation architecture - Conceptual, logical, and physical design methodology - Edge services and high availability design - Logical switching and routing design - Scalability, performance, and capacity planning |
| Architecture and Technologies | 22% | - NSX-T components and cluster design - Hypervisor networking integration - NSX-T Data Center logical and physical architecture - Management, control, and data plane separation |
| Security and Service Design | 15% | - Identity and access control model - Audit, compliance, and visibility design - Firewall, NAT, VPN, and load balancing design |
| Operations and Automation | 10% | - Backup, recovery, and upgrade planning - Management and monitoring architecture - API and automation integration |
| Products and Solutions | 18% | - Compatibility and interoperability requirements - NSX-T integration with vSphere, KVM, and cloud platforms - Coexistence with physical network infrastructure |
3V0-41.19 Exam FAQ: Preparation, Payment, and Facts
VMware recommends these training resources for candidates:
An effective training course builds understanding; scored practice with expert-verified answers builds exam readiness. The two work best together.
Yes. Real4Prep processes every purchase through a secure Credit Card payment system, so your transaction is protected from leakage or error at each step of the deal. We put customers' interests and the quality of the VMware Advanced Design NSX-T Data Center 2.4 product first — the 3V0-41.19 exam materials should be the only thing you need to think about after checkout.
The 3V0-41.19 exam contains 60 - 70 questions with 135 minutes minutes to complete them. Scored practice rounds under the same limit are how you find out — in advance — whether the clock will be a problem for you.
The official outline divides the 3V0-41.19 exam into weighted domains, including:
- Planning and Designing (35%)
- Security and Service Design (15%)
- Architecture and Technologies (22%)
The VMware Advanced Design NSX-T Data Center 2.4 practice questions at Real4Prep are organized around these same objectives, so your scored mock results map directly onto the areas that need work.
The 3V0-41.19 exam leads to the VMware Advanced Design NSX-T Data Center 2.4 certification from VMware, one of the more popular credentials among IT professionals — and it is genuinely not easy to pass. The workable approaches are well known: invest focused time and energy, take an effective training course, and practice with material that mirrors the real exam. Preparation quality, not luck, separates the attempts that succeed from the ones that need repeating.
Registration for the 3V0-41.19 exam runs through these official channels:
A good moment to register is when your scored practice results stay consistently strong — let measurement, not mood, set the date.
That is exactly what the software version is for. It recreates the atmosphere of the real 3V0-41.19 exam, and after each exercise you can assess your score and see your current level in concrete terms. Those results tell you whether you are grasping the key points or still circling them, so your remaining study time goes in the right direction — particularly valuable when work and family leave you only a few hours a week.
VCP-NV certification or equivalent experience with NSX-T/vSphere; recommended 2+ years of network virtualization design experience
Passing the 3V0-41.19 exam requires 300 / 500, and registration costs $450 USD. Think of preparation as the smaller investment that protects the larger one — measured, scored practice is how you make that trade a good one.
VMware Advanced Design NSX-T Data Center 2.4 Sample Questions:
An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.
During discussions about Centralized Services NAT running on Tier-1 or Tier-0 LR the customer made these requests:
* Services contain stateful services.
* Services should be in high availability mode.
Which two should the architect include in their design? (Choose two.)
- A. The high availability mode supported is only Active-Stand by.
- B. Mix stateful and stateless NAT rules on the same LR.
- C. NAT should be applied on the uplink Interface.
- D. Use only DNAT rules in stateful NAT.
- E. An active/active model should be used.
Correct Answer: A,D 🗳️
Explanation: Only visible for Real4Prep members. You can sign-up / login (it's free).
An architect is helping an organization design an NSX-T Data Center solution. This information was gathered during a workshop:
* There are three LUNs In the storage array.
* There is no additional budget to purchase any more hardware.
* LUN 1usage is 90% and is configured with a high-performance profile.
* LUN 2 usage is 75% and is configured with a high availability profile.
* LUN 3 usage is 60% and is configured with a balanced performance/availability profile.
* A highly available NSX Management cluster is required.
* ECMP routing is required.
Which should the architect recommend for the organization's NSX-T Datacenter environment?
- A. Place all three NSX Managers onLUN 1 to avoid latency.
- B. Place all three NSX Managers on LUN 2 for high availability.
- C. Spread the NSX Managers across LUN 2 and LUN 3.
- D. Spread the NSX Managers across the three LUNs.
Correct Answer: D 🗳️
Explanation: Only visible for Real4Prep members. You can sign-up / login (it's free).
An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during a workshop:
* Some workloads should be moved to a CloudProvider.
* Extend network's VLAN or VNI across sites on the same broadcast domain.
* Enable VM mobility use cases such as migration and disaster recovery without IP address changes.
* Support 1500 byte MTU between sites.
Which should thearchitect include in their design?
- A. Load Balancer
- B. SSL VPN
- C. Reflexive NAT
- D. L2 VPN
Correct Answer: D 🗳️
Explanation: Only visible for Real4Prep members. You can sign-up / login (it's free).
An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.
This information was gathered during the Assessment Phase:
* Customer Is concerned with NSX Manager availability.
* 3 cabinets/racks are available in the data center.
* No integration with 3rd party solution is required.
* There is no budget for physical equipment acquisition.
* The 3 cabinets/racks do not share the same L2 domain.
Which three should the architect include in their designto address the customer's concern with NSX Manager availability? (Choose three.)
- A. Deploy a single active NSX Manager appliance in rack 1.
- B. Use separate IP per NSX Manager appliance per rack.
- C. Use another NSX Manger IP in case an appliance falls.
- D. Deploy 2 cold standby NSX Manager appliances in rack 2/3.
- E. Deploy an NSX Manager Appliance per rackand cluster them.
- F. Use a physical/internal load-balancer with the cluster.
Correct Answer: B,E,F 🗳️
Explanation: Only visible for Real4Prep members. You can sign-up / login (it's free).
An architect is helpingan organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during the Assessment Phase:
* There Is a critical application used by the Finance Team.
* The critical application has an availability and recoverability SLA of 99.99%.
* The critical application Is sensitive to network changes.
Which two should an architect include in their design? (Choose two.)
- A. Enable BFD on Tier-0 gateway.
- B. Configure multiple static routes on Tier-1 gateway.
- C. Configure Tier-1 gateway for eBGP and ECMP.
- D. Configure Tler-0 gateway foreBGP and ECMP.
- E. Install and configure hosts with 100Gbps physical NICs.
Correct Answer: A,D 🗳️
Explanation: Only visible for Real4Prep members. You can sign-up / login (it's free).
Viewing page 1 out of 10 pages.
Viewing questions 1-5 out of 50 questions.