NEW QUESTION 12
Refer to the exhibit.

This image shows a CPU Pick-and-Place tool and a CPU Socket Protective Cap Removal tool.
Which types of Cisco UCS servers and Intel Xeon processors do these tools support?

  • A. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2600 Series processors
  • B. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2400 Series processors
  • C. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2600 Series processors
  • D. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2400 Series processors

Answer: A

 

NEW QUESTION 13
Refer to the exhibit.

Where is the best place to see bootflash free space?

  • A. A - Available Memory
  • B. B - Total Memory
  • C. D - High Availability Details
  • D. C - Local Storage Information

Answer: D

 

NEW QUESTION 14
Which two statements about Cisco UCS S3260 Storage Server are true? (Choose two.)

  • A. Massive 840-TB data storage capacity
  • B. It is in a compact 2-RU form factor.
  • C. Up to 1 TB of Intel Optane DC Persistent Memory
  • D. Support for the Cisco 12-G 9460-8i PCIe SAS RAID controller
  • E. AMD EPYC 7000 series processors, with up to 32 cores per socket

Answer: A,D

Explanation:
Explanation/Reference: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-s-series- storage-servers/s3260-specsheet.pdf

 

NEW QUESTION 15
Refer to the exhibit.

What does it mean when item 7 (System Status LED) has a blinking red status?

  • A. Power on Self-Test (POST) failed
  • B. Major fault with memory DIMM
  • C. Major fault with the system board
  • D. Secure boot validation has failed
  • E. Power shut down by software

Answer: A

 

NEW QUESTION 16
Which two statements about DIMM replacement in Cisco UCS Servers are true? (Choose two.)

  • A. If the memory in a server is not fully populated, you can install DIMMs in any open slot.
  • B. In servers that require pairs of DIMMs, the pairs must be identical (manufacturer, size, part #, and so on).
  • C. Rack-mount and blade servers have memory fault LEDs that indicate which DIMM requires attention.
  • D. In blade servers, DIMMs can be installed in either 1, 2, 4, or 8 DIMMs per channel.

Answer: B,D

 

NEW QUESTION 17
What is Platform as a Service?

  • A. It configures, manages and develops networking environment for your application.
  • B. It is the software development framework and components delivered over the network on a pay-as-you-go basis.
  • C. It is where servers and virtual machines (VMs), network and storage are delivered over the network on a pay-as-you-go basis.
  • D. It is when an application service is delivered over the network on a subscription basis.

Answer: B

 

NEW QUESTION 18
Which two statements about FCoE are true? (Choose two.)

  • A. It allows Ethernet traffic to run over a Fibre Channel infrastructure.
  • B. Encapsulates Ethernet frames into Fibre Channel frames, which allows them to run alongside traditional IP traffic.
  • C. Allows Fibre Channel and Ethernet networks to share a single, integrated infrastructure.
  • D. Consolidates I/O traffic in the data center.
  • E. Increases capital costs due to the difficulty to manage.

Answer: C,D

 

NEW QUESTION 19
On which three devices can the Host Upgrade Utility be performed? (Choose three.)

  • A. B230
  • B. B460
  • C. C210
  • D. C420
  • E. C230
  • F. C240
  • G. B210

Answer: C,D,F

 

NEW QUESTION 20
When replacing a standalone C-Series server which order will be used to shut down the server via CIMC?

  • A. Click Host power, Click Shut off
  • B. Click Power off, Click Shut down
  • C. Click Power off, Click Shut off
  • D. Click Host power, Click Shut down

Answer: B

 

NEW QUESTION 21
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?

  • A. second-generation supervisor enhanced module (Sup2E)
  • B. first-generation supervisor module
  • C. third-generation supervisor enhanced module (Sup3E)
  • D. second-generation supervisor module (Sup2)

Answer: A

 

NEW QUESTION 22
Which two virtualization technologies are used in a modern data center design? (Choose two.)

  • A. Application virtualization
  • B. Server virtualization
  • C. Cloud virtualization
  • D. Platform virtualization
  • E. Storage virtualization

Answer: B,D

 

NEW QUESTION 23
With which data center type can a company lease the equipment and infrastructure?

  • A. Managed services data center
  • B. Enterprise data center
  • C. Green technology data center
  • D. Colocation data center

Answer: A

 

NEW QUESTION 24
How many 10GBASE-T port licenses are preinstalled on a Cisco Nexus 3064-32T?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 25
A company wants to build a data center infrastructure which can provide up to 99.982% uptime availability per year. Which ANSI/TIA-942 data center tier meets the requirement?

  • A. Concurrently maintainable site infrastructure
  • B. Redundant-distribution site infrastructure
  • C. Basic site infrastructure
  • D. Redundant-capacity component site infrastructure

Answer: A

Explanation:
Explanation/Reference: https://www.doc.ic.ac.uk/~jgiceva/teaching/ssc18-cloud.pdf page 16

 

NEW QUESTION 26
Which five things should the administrator verify after performing maintenance or replacing a blade server? (Choose five.)

  • A. hard drive status
  • B. mezzanine card status
  • C. host OS boot status
  • D. CPU status
  • E. blade server status
  • F. fan and power status
  • G. memory DIMM status

Answer: A,B,D,E,G

 

NEW QUESTION 27
Which statement is true about cloud computing?

  • A. Users usually own and maintain their own IT infrastructure and facility.
  • B. It increases total cost of ownership.
  • C. It provides self-service, on-demand provisioning and a billing for corporate usage only.
  • D. It provides end-to-end server, application network service, and storage virtualization.

Answer: D

 

NEW QUESTION 28
When activating the firmware via UCSM which two firmware versions must be activated at the same time?

  • A. System and Kernel
  • B. UCS Manger and Kernel
  • C. UCS Manager and System
  • D. CIMC and Kernel

Answer: A

 

NEW QUESTION 29
Which type of optics module is supported by a 12-port 100 GE Cisco Nexus 7700 F3 Series I/O module?

  • A. QSFP+
  • B. SFP/SFP+
  • C. CFP
  • D. CPAK

Answer: D

 

NEW QUESTION 30
Which two remote file system methods are used in the training material to transfer firmware to the Fabric Interconnect? (Choose two.)

  • A. FTP
  • B. TFTP
  • C. FTPS
  • D. RSH

Answer: A,B

 

NEW QUESTION 31
Which three tools are necessary to console into a Cisco UCS C-Series Rack-Mount Server? (Choose three.)

  • A. Cisco DB-9-to-RJ-45 console cable
  • B. keyboard
  • C. KVM dongle
  • D. USB serial adapter
  • E. laptop
  • F. monitor

Answer: B,C,F

Explanation:
Explanation/Reference:
answer is well modified.

 

NEW QUESTION 32
Which two firmware components does the Host Upgrade Utility upgrade? (Choose two.)

  • A. System BIOS
  • B. Fabric Interconnect firmware
  • C. CIMC
  • D. Cisco UCS Infrastructure software
  • E. Cisco UCS Manager

Answer: A,C

Explanation:
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/lomug/2-0-x/3_0/b_huu_3_0_1/ b_huu_2_0_13_chapter_011.html

 

NEW QUESTION 33
Refer to the exhibit.

Where is the best place to see whether the system is ready for a Fabric Interconnect failover?

  • A. E - High Availability Details
  • B. D - Access
  • C. C - Part Details
  • D. A - Overall Status operable
  • E. B - L1 Connection

Answer: A

 

NEW QUESTION 34
A company wants to build a data center infrastructure which can provide up to 99.982% uptime availability per year. Which ANSI/TIA-942 data center tier meets the requirement?

  • A. Concurrently maintainable site infrastructure
  • B. Redundant-distribution site infrastructure
  • C. Basic site infrastructure
  • D. Redundant-capacity component site infrastructure

Answer: A

 